語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
RF magnetic field, specific energy a...
~
Liu, Wanzhan.
FindBook
Google Book
Amazon
博客來
RF magnetic field, specific energy absorption rate, and signal to noise ratio in MRI: Experiments and numerical calculations with finite difference time domain method.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
RF magnetic field, specific energy absorption rate, and signal to noise ratio in MRI: Experiments and numerical calculations with finite difference time domain method./
作者:
Liu, Wanzhan.
面頁冊數:
164 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-05, Section: B, page: 2694.
Contained By:
Dissertation Abstracts International66-05B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3173803
ISBN:
0542115980
RF magnetic field, specific energy absorption rate, and signal to noise ratio in MRI: Experiments and numerical calculations with finite difference time domain method.
Liu, Wanzhan.
RF magnetic field, specific energy absorption rate, and signal to noise ratio in MRI: Experiments and numerical calculations with finite difference time domain method.
- 164 p.
Source: Dissertation Abstracts International, Volume: 66-05, Section: B, page: 2694.
Thesis (Ph.D.)--The Pennsylvania State University, 2005.
When MRI moves towards higher fields for higher signal to noise ratio (SNR), one of the challenges is that the complicated interaction between the radiofrequency (RF) field and the biological tissues degrades the performance of the system. The finite difference time domain (FDTD) numerical method for electromagnetism, verified by experiments, is a valuable tool to study the RF field in high field MRI. The RF magnetic (B1) field distribution and the SNR for different end-ring/shield configurations in birdcage-type RF coils are examined numerically at 64 and 125 MHz and experimentally at 125 MHz. With the previously developed male body model, a new anatomically accurate female body model is developed to study B1 field distribution, SNR, and specific energy absorption rate (SAR) in different body types at 64 MHz and 128 MHz. The RF radiation loss, which is associated with SNR and SAR, in a surface coil, a head size birdcage coil, and a head size TEM coil loaded with phantoms at a frequency range from 64 MHz to 600 MHz is also evaluated numerically. It is found that (a) the end-ring/shield configuration in a birdcage coil affects B1 homogeneity and SNR in a head, (b) loading a larger, more muscular subject results in significantly less homogeneous B+1 distribution, lower SNR, higher SAR levels, and (c) the radiation becomes significant at high fields and the interaction between the RF field and the dielectric material in the sample helps to reduce the radiation. These results provide useful information for RF design and MRI safety guideline at high fields.
ISBN: 0542115980Subjects--Topical Terms:
1017684
Engineering, Biomedical.
RF magnetic field, specific energy absorption rate, and signal to noise ratio in MRI: Experiments and numerical calculations with finite difference time domain method.
LDR
:02571nmm 2200277 4500
001
1818352
005
20060908150228.5
008
130610s2005 eng d
020
$a
0542115980
035
$a
(UnM)AAI3173803
035
$a
AAI3173803
040
$a
UnM
$c
UnM
100
1
$a
Liu, Wanzhan.
$3
1907687
245
1 0
$a
RF magnetic field, specific energy absorption rate, and signal to noise ratio in MRI: Experiments and numerical calculations with finite difference time domain method.
300
$a
164 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-05, Section: B, page: 2694.
500
$a
Adviser: Michael B. Smith.
502
$a
Thesis (Ph.D.)--The Pennsylvania State University, 2005.
520
$a
When MRI moves towards higher fields for higher signal to noise ratio (SNR), one of the challenges is that the complicated interaction between the radiofrequency (RF) field and the biological tissues degrades the performance of the system. The finite difference time domain (FDTD) numerical method for electromagnetism, verified by experiments, is a valuable tool to study the RF field in high field MRI. The RF magnetic (B1) field distribution and the SNR for different end-ring/shield configurations in birdcage-type RF coils are examined numerically at 64 and 125 MHz and experimentally at 125 MHz. With the previously developed male body model, a new anatomically accurate female body model is developed to study B1 field distribution, SNR, and specific energy absorption rate (SAR) in different body types at 64 MHz and 128 MHz. The RF radiation loss, which is associated with SNR and SAR, in a surface coil, a head size birdcage coil, and a head size TEM coil loaded with phantoms at a frequency range from 64 MHz to 600 MHz is also evaluated numerically. It is found that (a) the end-ring/shield configuration in a birdcage coil affects B1 homogeneity and SNR in a head, (b) loading a larger, more muscular subject results in significantly less homogeneous B+1 distribution, lower SNR, higher SAR levels, and (c) the radiation becomes significant at high fields and the interaction between the RF field and the dielectric material in the sample helps to reduce the radiation. These results provide useful information for RF design and MRI safety guideline at high fields.
590
$a
School code: 0176.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0574
710
2 0
$a
The Pennsylvania State University.
$3
699896
773
0
$t
Dissertation Abstracts International
$g
66-05B.
790
1 0
$a
Smith, Michael B.,
$e
advisor
790
$a
0176
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3173803
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9209215
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入