語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Biostability of polyurethane elastom...
~
Wiggins, Michael John.
FindBook
Google Book
Amazon
博客來
Biostability of polyurethane elastomers: Pacemaker leads, effect of fatigue, and novel antioxidant stabilizers.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Biostability of polyurethane elastomers: Pacemaker leads, effect of fatigue, and novel antioxidant stabilizers./
作者:
Wiggins, Michael John.
面頁冊數:
166 p.
附註:
Source: Dissertation Abstracts International, Volume: 63-07, Section: B, page: 3378.
Contained By:
Dissertation Abstracts International63-07B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3058378
ISBN:
0493742689
Biostability of polyurethane elastomers: Pacemaker leads, effect of fatigue, and novel antioxidant stabilizers.
Wiggins, Michael John.
Biostability of polyurethane elastomers: Pacemaker leads, effect of fatigue, and novel antioxidant stabilizers.
- 166 p.
Source: Dissertation Abstracts International, Volume: 63-07, Section: B, page: 3378.
Thesis (Ph.D.)--Case Western Reserve University, 2002.
The failure mechanism of bipolar coaxial pacemaker leads was investigated with infrared (IR) microspectroscopy and scanning electron microscopy (SEM). Upon dissection of several failed leads, the poly(etherurethane) (PEU) inner insulation showed highly localized regions of environmental stress cracking (ESC) which were likely responsible for lead failure. Based on IR and SEM evidence, it was proposed that relatively stable hydrogen peroxide produced by adherent cells permeated through the outer silicone sheath and upon contact with the outer conducting coil decomposed into reactive oxygen radicals. These radicals then oxidized the PEU.
ISBN: 0493742689Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Biostability of polyurethane elastomers: Pacemaker leads, effect of fatigue, and novel antioxidant stabilizers.
LDR
:03272nmm 2200325 4500
001
1817871
005
20060829133352.5
008
130610s2002 eng d
020
$a
0493742689
035
$a
(UnM)AAI3058378
035
$a
AAI3058378
040
$a
UnM
$c
UnM
100
1
$a
Wiggins, Michael John.
$3
1907216
245
1 0
$a
Biostability of polyurethane elastomers: Pacemaker leads, effect of fatigue, and novel antioxidant stabilizers.
300
$a
166 p.
500
$a
Source: Dissertation Abstracts International, Volume: 63-07, Section: B, page: 3378.
500
$a
Advisers: Anne Hiltner; James M. Anderson.
502
$a
Thesis (Ph.D.)--Case Western Reserve University, 2002.
520
$a
The failure mechanism of bipolar coaxial pacemaker leads was investigated with infrared (IR) microspectroscopy and scanning electron microscopy (SEM). Upon dissection of several failed leads, the poly(etherurethane) (PEU) inner insulation showed highly localized regions of environmental stress cracking (ESC) which were likely responsible for lead failure. Based on IR and SEM evidence, it was proposed that relatively stable hydrogen peroxide produced by adherent cells permeated through the outer silicone sheath and upon contact with the outer conducting coil decomposed into reactive oxygen radicals. These radicals then oxidized the PEU.
520
$a
A method utilizing expansion of a diaphragm-type film specimen was developed to study in vitro biodegradation of poly(etherurethane urea) (PEUU) under conditions of dynamic loading (fatigue). The geometry of deformation allowed uniaxial and biaxial stress to be tested simultaneously. Dynamic loading did not affect the rate of degradation relative to unstressed and constant stress (creep) controls in regions of the film that experienced primarily uniaxial fatigue, however degradation was accelerated in regions that experienced almost equibiaxial fatigue. It was concluded that the combination of dynamic loading and biaxial tensile strain accelerated oxidative degradation in this system. The rate of degradation was highly strain rate dependent. Chemical degradation produced a brittle surface layer that was marked by numerous pits and dimples. Physical damage of the surface in the form of cracking occurred only in fatigue experiments. Cracking was not observed in unstressed or creep experiments. Cracks initiated at dimples produced by chemical degradation, and propagated in a direction that was determined by the strain state.
520
$a
Two different approaches to control PU biodegradation were tested. Both approaches attempted to modify the surface of the PU, instead of the bulk. The first approach used synthetic molecules covalently bound to the surface of a PU to act as catalytic antioxidants. The second approach was to modify the surface to prevent cell adhesion. The challenge in using these approaches is controlling the stability and uniformity of surface modification.
590
$a
School code: 0042.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Plastics Technology.
$3
1023683
650
4
$a
Chemistry, Polymer.
$3
1018428
690
$a
0541
690
$a
0795
690
$a
0495
710
2 0
$a
Case Western Reserve University.
$3
1017714
773
0
$t
Dissertation Abstracts International
$g
63-07B.
790
1 0
$a
Hiltner, Anne,
$e
advisor
790
1 0
$a
Anderson, James M.,
$e
advisor
790
$a
0042
791
$a
Ph.D.
792
$a
2002
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3058378
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9208734
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入