Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Methods for improving microwave radi...
~
Cox, Amanda E.
Linked to FindBook
Google Book
Amazon
博客來
Methods for improving microwave radiometer calibration and data quality for geophysical applications.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Methods for improving microwave radiometer calibration and data quality for geophysical applications./
Author:
Cox, Amanda E.
Description:
192 p.
Notes:
Source: Dissertation Abstracts International, Volume: 65-02, Section: B, page: 0858.
Contained By:
Dissertation Abstracts International65-02B.
Subject:
Engineering, Aerospace. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3123236
Methods for improving microwave radiometer calibration and data quality for geophysical applications.
Cox, Amanda E.
Methods for improving microwave radiometer calibration and data quality for geophysical applications.
- 192 p.
Source: Dissertation Abstracts International, Volume: 65-02, Section: B, page: 0858.
Thesis (Ph.D.)--University of Colorado at Boulder, 2004.
Research on methods to improve microwave radiometer calibration and data quality is presented. The investigations chosen were those relevant to the Airborne Imaging Microwave Radiometer (AIMR) at the National Center for Atmospheric Research, Atmospheric Technology Division, but are applicable to other passive microwave instruments. Instrument calibration was determined through comparison of output brightness temperatures to a microwave radiative transfer model, through analysis of data obtained from the application of different calibration methods, and through an inter-comparison between AIMR and the Surface Based Radiometer. AIMR data shows good agreement with the model and a comparison between a tipping calibration and calibration from AIMR internal calibration targets yields similar results. The magnitude of the brightness temperature uncertainty for typical scene temperatures (152--200 K) is estimated at 2 K. The uncertainty for colder scene temperatures is higher. Data utility was improved through several investigations and the modification of calibration algorithms to reduce data uncertainty and improve image quality. Coupling of the cold scene temperature into the measurement of the hot calibration load is identified as a contributor to reduced image quality. Gradients in the AIMR calibration targets are investigated through the use of infrared imaging. A gradient of about 1.3 K across the face of the AIMR target is measured. Ground work is laid for future investigations into the infrared properties of passive microwave calibration targets. A calibration sample averaging scheme that is consistent with the stability of the calibration system is proposed. Modifications of AIMR post-processing software to correct the application of the calibration algorithm are tested and result in a reduction in the brightness temperature uncertainty by 0.3 K. The utility of airborne passive microwave sensors is enhanced through the development of a novel geolocation device to aid in precise alignment of sensor imagery with ground locations. This technique has applications for validation efforts, where airborne measurements need to be aligned with in-situ measurements on the Earth's surface, as well as for other field projects.Subjects--Topical Terms:
1018395
Engineering, Aerospace.
Methods for improving microwave radiometer calibration and data quality for geophysical applications.
LDR
:03150nmm 2200265 4500
001
1810939
005
20041216102950.5
008
130614s2004 eng d
035
$a
(UnM)AAI3123236
035
$a
AAI3123236
040
$a
UnM
$c
UnM
100
1
$a
Cox, Amanda E.
$3
1900530
245
1 0
$a
Methods for improving microwave radiometer calibration and data quality for geophysical applications.
300
$a
192 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-02, Section: B, page: 0858.
500
$a
Director: Judith A. Curry.
502
$a
Thesis (Ph.D.)--University of Colorado at Boulder, 2004.
520
$a
Research on methods to improve microwave radiometer calibration and data quality is presented. The investigations chosen were those relevant to the Airborne Imaging Microwave Radiometer (AIMR) at the National Center for Atmospheric Research, Atmospheric Technology Division, but are applicable to other passive microwave instruments. Instrument calibration was determined through comparison of output brightness temperatures to a microwave radiative transfer model, through analysis of data obtained from the application of different calibration methods, and through an inter-comparison between AIMR and the Surface Based Radiometer. AIMR data shows good agreement with the model and a comparison between a tipping calibration and calibration from AIMR internal calibration targets yields similar results. The magnitude of the brightness temperature uncertainty for typical scene temperatures (152--200 K) is estimated at 2 K. The uncertainty for colder scene temperatures is higher. Data utility was improved through several investigations and the modification of calibration algorithms to reduce data uncertainty and improve image quality. Coupling of the cold scene temperature into the measurement of the hot calibration load is identified as a contributor to reduced image quality. Gradients in the AIMR calibration targets are investigated through the use of infrared imaging. A gradient of about 1.3 K across the face of the AIMR target is measured. Ground work is laid for future investigations into the infrared properties of passive microwave calibration targets. A calibration sample averaging scheme that is consistent with the stability of the calibration system is proposed. Modifications of AIMR post-processing software to correct the application of the calibration algorithm are tested and result in a reduction in the brightness temperature uncertainty by 0.3 K. The utility of airborne passive microwave sensors is enhanced through the development of a novel geolocation device to aid in precise alignment of sensor imagery with ground locations. This technique has applications for validation efforts, where airborne measurements need to be aligned with in-situ measurements on the Earth's surface, as well as for other field projects.
590
$a
School code: 0051.
650
4
$a
Engineering, Aerospace.
$3
1018395
650
4
$a
Remote Sensing.
$3
1018559
690
$a
0538
690
$a
0799
710
2 0
$a
University of Colorado at Boulder.
$3
1019435
773
0
$t
Dissertation Abstracts International
$g
65-02B.
790
1 0
$a
Curry, Judith A.,
$e
advisor
790
$a
0051
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3123236
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
2 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9182573
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
W9185598
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
2 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login