Evaluation of ozone treatment, pilot...
~
Sandu, Simonel Ioan.
Linked to FindBook
Google Book
Amazon
博客來
Evaluation of ozone treatment, pilot-scale wastewater treatment plant, and nitrogen budget for Blue Ridge Aquaculture.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Evaluation of ozone treatment, pilot-scale wastewater treatment plant, and nitrogen budget for Blue Ridge Aquaculture./
Author:
Sandu, Simonel Ioan.
Description:
333 p.
Notes:
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0010.
Contained By:
Dissertation Abstracts International66-01B.
Subject:
Engineering, Environmental. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3161927
ISBN:
9780496955114
Evaluation of ozone treatment, pilot-scale wastewater treatment plant, and nitrogen budget for Blue Ridge Aquaculture.
Sandu, Simonel Ioan.
Evaluation of ozone treatment, pilot-scale wastewater treatment plant, and nitrogen budget for Blue Ridge Aquaculture.
- 333 p.
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0010.
Thesis (Ph.D.)--Virginia Polytechnic Institute and State University, 2004.
Sustainable tilapia production at Blue Ridge Aquaculture (BRA) is constrained by availability of high quality replacement water. I developed a pilot-scale wastewater treatment system to treat and reuse effluent presently discharged. An initial study was conducted to determine the response of the BRA waste stream to ozone application. Dosages of 6.9, 4.8 and 2.4 g O3 were applied for 30 minutes to 35 L of settled effluent. Optimum ozone dosage and reaction time, ozone transfer efficiency, ozone yield coefficient, degree of pollutant removal, and other ozone and water quality parameters were determined. Most results suggested that the maximum process feasibility limit for ozone contact time was approximately 9 minutes at an applied ozone concentration of 23g/m3 (6.9 g O3 dose). Formation of foam increased solids and COD removal up to three times. Poor removal or accumulation of DOC and TAN was observed, indicating the need for biological treatment following ozonation.
ISBN: 9780496955114Subjects--Topical Terms:
783782
Engineering, Environmental.
Evaluation of ozone treatment, pilot-scale wastewater treatment plant, and nitrogen budget for Blue Ridge Aquaculture.
LDR
:03224nam 2200313 4500
001
1404391
005
20111205104740.5
008
130515s2004 ||||||||||||||||| ||eng d
020
$a
9780496955114
035
$a
(UMI)AAI3161927
035
$a
AAI3161927
040
$a
UMI
$c
UMI
100
1
$a
Sandu, Simonel Ioan.
$3
1683710
245
1 0
$a
Evaluation of ozone treatment, pilot-scale wastewater treatment plant, and nitrogen budget for Blue Ridge Aquaculture.
300
$a
333 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-01, Section: B, page: 0010.
500
$a
Chair: Eric M. Hallerman.
502
$a
Thesis (Ph.D.)--Virginia Polytechnic Institute and State University, 2004.
520
$a
Sustainable tilapia production at Blue Ridge Aquaculture (BRA) is constrained by availability of high quality replacement water. I developed a pilot-scale wastewater treatment system to treat and reuse effluent presently discharged. An initial study was conducted to determine the response of the BRA waste stream to ozone application. Dosages of 6.9, 4.8 and 2.4 g O3 were applied for 30 minutes to 35 L of settled effluent. Optimum ozone dosage and reaction time, ozone transfer efficiency, ozone yield coefficient, degree of pollutant removal, and other ozone and water quality parameters were determined. Most results suggested that the maximum process feasibility limit for ozone contact time was approximately 9 minutes at an applied ozone concentration of 23g/m3 (6.9 g O3 dose). Formation of foam increased solids and COD removal up to three times. Poor removal or accumulation of DOC and TAN was observed, indicating the need for biological treatment following ozonation.
520
$a
Next, I evaluated a pilot station treatment train including sedimentation, microscreen filtration, fluidized bed denitrification, ozonation, aerobic biological oxidation in a trickling filter, and jar-test chemical flocculation. Significant improvements were found regarding solids, COD, cBOD5, NO3--N, TKN, and turbidity. Removal of foam after ozonation improved ozonation efficacy and pollutant removal.
520
$a
A nitrogen budget for the BRA facility was derived, indicating that 35% of the nitrogen applied in feed was assimilated in fish. I evaluated the possible impact of residual inorganic nitrogen forms from treated effluent upon fish in the recirculating systems. I found that less than 1% of the TAN produced would return the recovered stream, and that the existing biological contactors can remove it. Evaluation of TAN fate indicated that 84% was oxidized in biofilters, 14% was oxidized by passive nitrification, and 1% was removed by water exchange. For NO3-N, I determined that 56% was removed by passive denitrification and 44% by daily water exchange.
520
$a
The pilot station design was effective for removing organics and nutrients, and can serve as the basis for scale-up for treating and reusing the entire BRA effluent stream.
590
$a
School code: 0247.
650
4
$a
Engineering, Environmental.
$3
783782
650
4
$a
Agriculture, Fisheries and Aquaculture.
$3
1020913
690
$a
0775
690
$a
0792
710
2
$a
Virginia Polytechnic Institute and State University.
$3
1017496
773
0
$t
Dissertation Abstracts International
$g
66-01B.
790
1 0
$a
Hallerman, Eric M.,
$e
advisor
790
$a
0247
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3161927
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9167530
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login