Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Polymer and Tissue Separation and Mi...
~
Huang, Huan.
Linked to FindBook
Google Book
Amazon
博客來
Polymer and Tissue Separation and Micro/Nano- Fabrication via Ultra-Short Pulsed Laser Plasma-Mediated Ablation.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Polymer and Tissue Separation and Micro/Nano- Fabrication via Ultra-Short Pulsed Laser Plasma-Mediated Ablation./
Author:
Huang, Huan.
Description:
211 p.
Notes:
Source: Dissertation Abstracts International, Volume: 72-03, Section: B, page: .
Contained By:
Dissertation Abstracts International72-03B.
Subject:
Chemistry, Polymer. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3434760
ISBN:
9781124420196
Polymer and Tissue Separation and Micro/Nano- Fabrication via Ultra-Short Pulsed Laser Plasma-Mediated Ablation.
Huang, Huan.
Polymer and Tissue Separation and Micro/Nano- Fabrication via Ultra-Short Pulsed Laser Plasma-Mediated Ablation.
- 211 p.
Source: Dissertation Abstracts International, Volume: 72-03, Section: B, page: .
Thesis (Ph.D.)--Rutgers The State University of New Jersey - New Brunswick, 2010.
Micro/nano-fabrication of polymers and micro-processing of real human tissues via plasma-mediated ablation were investigated using an ultra-short pulsed (USP) laser of 900 fs pulse duration and 1552 nm center wavelength. For the PDMS polymer micro-fabrication, the ablation threshold for the single spot and the single line scanning ablation features were studied at first. The single pulse ablation threshold is determined to be 4.62 J/cm 2 and the incubation factor for the multi-pulse ablation is found to be 0.52. The influences of pulse overlap rate and irradiation pulse energy on the ablation line width, internal ablation interface depth, and ablation surface quality were scrutinized. Then the thin layer PDMS separation was completed with thickness controllable via adjusting the laser focus spot position. For the three tests with a target thickness of 20 mum, the averaged thickness of the separated thin layers is 20.6+/- 1.7 mum. And a multi-width micro-channel interconnected network was fabricated and the size of the channels varies from 50 to 400 mum. For the real tissue ablation, the fundamental ablation features were investigated. It is found that the threshold of the single pulse ablation for the freeze-dried dermis (8.32+/-0.37 J/cm 2) is slightly smaller than that of the wet dermis (9.65+/-1.21 J/cm2) due to the light absorption of water in wet tissues. Histological examinations were performed to evaluate the thermal damage and to find appropriate laser parameters for tissue micro-processing with minimal thermal damage. An analytical solution based on the heat conduction equation was derived to analyze the temperature distributions and to obtain the heat affected zones in materials ablated by USP laser line scanning. The analytical results were compared with the experimental measurements and a good agreement was found. Both results show that the thermal damage can be confined in a small zone about 10 mum with proper pulse energy and overlap rate. Pulse energy and pulse overlap rate were the key parameters for the generation and severity of thermal damage. In vitro wet tissue separation into layers by the USP laser ablation was demonstrated with thickness ranging from 200 to 600 mum. The unevenness of the separated layers is under 10%. Freeze-dried tissue stripping was also demonstrated with the stripped thickness in the range of 20 - 40 mum. No sign of visible thermal damage was found for both types of tissues. This study has provided an effective method that can precisely and non-intrusively process polymers and tissues with minimized thermal damage.
ISBN: 9781124420196Subjects--Topical Terms:
1018428
Chemistry, Polymer.
Polymer and Tissue Separation and Micro/Nano- Fabrication via Ultra-Short Pulsed Laser Plasma-Mediated Ablation.
LDR
:03554nam 2200277 4500
001
1396025
005
20110527105451.5
008
130515s2010 ||||||||||||||||| ||eng d
020
$a
9781124420196
035
$a
(UMI)AAI3434760
035
$a
AAI3434760
040
$a
UMI
$c
UMI
100
1
$a
Huang, Huan.
$3
1674777
245
1 0
$a
Polymer and Tissue Separation and Micro/Nano- Fabrication via Ultra-Short Pulsed Laser Plasma-Mediated Ablation.
300
$a
211 p.
500
$a
Source: Dissertation Abstracts International, Volume: 72-03, Section: B, page: .
500
$a
Adviser: Zhixiong Guo.
502
$a
Thesis (Ph.D.)--Rutgers The State University of New Jersey - New Brunswick, 2010.
520
$a
Micro/nano-fabrication of polymers and micro-processing of real human tissues via plasma-mediated ablation were investigated using an ultra-short pulsed (USP) laser of 900 fs pulse duration and 1552 nm center wavelength. For the PDMS polymer micro-fabrication, the ablation threshold for the single spot and the single line scanning ablation features were studied at first. The single pulse ablation threshold is determined to be 4.62 J/cm 2 and the incubation factor for the multi-pulse ablation is found to be 0.52. The influences of pulse overlap rate and irradiation pulse energy on the ablation line width, internal ablation interface depth, and ablation surface quality were scrutinized. Then the thin layer PDMS separation was completed with thickness controllable via adjusting the laser focus spot position. For the three tests with a target thickness of 20 mum, the averaged thickness of the separated thin layers is 20.6+/- 1.7 mum. And a multi-width micro-channel interconnected network was fabricated and the size of the channels varies from 50 to 400 mum. For the real tissue ablation, the fundamental ablation features were investigated. It is found that the threshold of the single pulse ablation for the freeze-dried dermis (8.32+/-0.37 J/cm 2) is slightly smaller than that of the wet dermis (9.65+/-1.21 J/cm2) due to the light absorption of water in wet tissues. Histological examinations were performed to evaluate the thermal damage and to find appropriate laser parameters for tissue micro-processing with minimal thermal damage. An analytical solution based on the heat conduction equation was derived to analyze the temperature distributions and to obtain the heat affected zones in materials ablated by USP laser line scanning. The analytical results were compared with the experimental measurements and a good agreement was found. Both results show that the thermal damage can be confined in a small zone about 10 mum with proper pulse energy and overlap rate. Pulse energy and pulse overlap rate were the key parameters for the generation and severity of thermal damage. In vitro wet tissue separation into layers by the USP laser ablation was demonstrated with thickness ranging from 200 to 600 mum. The unevenness of the separated layers is under 10%. Freeze-dried tissue stripping was also demonstrated with the stripped thickness in the range of 20 - 40 mum. No sign of visible thermal damage was found for both types of tissues. This study has provided an effective method that can precisely and non-intrusively process polymers and tissues with minimized thermal damage.
590
$a
School code: 0190.
650
4
$a
Chemistry, Polymer.
$3
1018428
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0495
690
$a
0548
710
2
$a
Rutgers The State University of New Jersey - New Brunswick.
$b
Graduate School - New Brunswick.
$3
1019196
773
0
$t
Dissertation Abstracts International
$g
72-03B.
790
1 0
$a
Guo, Zhixiong,
$e
advisor
790
$a
0190
791
$a
Ph.D.
792
$a
2010
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3434760
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9159164
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login