Enhanced indoor humidity control in ...
~
Xu, Xiang-guo.
Linked to FindBook
Google Book
Amazon
博客來
Enhanced indoor humidity control in a space served by a direct expansion (DX) air conditioning (A/C) system.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Enhanced indoor humidity control in a space served by a direct expansion (DX) air conditioning (A/C) system./
Author:
Xu, Xiang-guo.
Description:
182 p.
Notes:
Source: Dissertation Abstracts International, Volume: 71-11, Section: B, page: 7046.
Contained By:
Dissertation Abstracts International71-11B.
Subject:
Engineering, Architectural. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3429796
ISBN:
9781124292878
Enhanced indoor humidity control in a space served by a direct expansion (DX) air conditioning (A/C) system.
Xu, Xiang-guo.
Enhanced indoor humidity control in a space served by a direct expansion (DX) air conditioning (A/C) system.
- 182 p.
Source: Dissertation Abstracts International, Volume: 71-11, Section: B, page: 7046.
Thesis (Ph.D.)--Hong Kong Polytechnic University (Hong Kong), 2010.
The use of Direct-Expansion (DX) air conditioning (A/C) systems offers many advantages. However, most DX A/C systems are equipped with single-speed compressor and supply fan, relying on On-Off cycling compressor as a low-cost approach to maintaining only indoor air dry-bulb temperature, whereas the indoor air humidity is not controlled directly. In a hot and humid climate like Hong Kong, indoor humidity may remain at a high level in a space served by an On-Off controlled DX A/C System. A poor indoor humidity control can cause discomfort to occupants and degrade indoor air quality, and decrease the energy efficiency of an air conditioning system.
ISBN: 9781124292878Subjects--Topical Terms:
1671790
Engineering, Architectural.
Enhanced indoor humidity control in a space served by a direct expansion (DX) air conditioning (A/C) system.
LDR
:02922nam 2200289 4500
001
1395455
005
20110518115255.5
008
130515s2010 ||||||||||||||||| ||eng d
020
$a
9781124292878
035
$a
(UMI)AAI3429796
035
$a
AAI3429796
040
$a
UMI
$c
UMI
100
1
$a
Xu, Xiang-guo.
$3
1674148
245
1 0
$a
Enhanced indoor humidity control in a space served by a direct expansion (DX) air conditioning (A/C) system.
300
$a
182 p.
500
$a
Source: Dissertation Abstracts International, Volume: 71-11, Section: B, page: 7046.
500
$a
Adviser: Ming-yin Chan.
502
$a
Thesis (Ph.D.)--Hong Kong Polytechnic University (Hong Kong), 2010.
520
$a
The use of Direct-Expansion (DX) air conditioning (A/C) systems offers many advantages. However, most DX A/C systems are equipped with single-speed compressor and supply fan, relying on On-Off cycling compressor as a low-cost approach to maintaining only indoor air dry-bulb temperature, whereas the indoor air humidity is not controlled directly. In a hot and humid climate like Hong Kong, indoor humidity may remain at a high level in a space served by an On-Off controlled DX A/C System. A poor indoor humidity control can cause discomfort to occupants and degrade indoor air quality, and decrease the energy efficiency of an air conditioning system.
520
$a
This thesis addresses the indoor humidity control using DX A/C systems. It firstly presents a study on condensate retention on a louver-fin-and-tube air cooling and dehumidification coil, which is commonly used in DX A/C systems. Compared to previously related work focusing on the influence of condensate retention on the heat and mass transfer between air and a cooling coil, the study emphasizes the impacts of operating parameters on condensate retention on a cooling coil. Secondly, a new model for evaluating the wet fin efficiency of cooling and dehumidification coils has been developed and is reported. The condensate film moving on fin surfaces and its impacts on heat and mass transfer have been taken into account. Thirdly, an experimental study on the inherent correlations between the total output cooling capacity and the Equipment Sensible Heat Ratio (SHR) of a DX A/C system is reported. Finally, a new control algorithm, named H-L control, to replace the traditional On-Off control algorithm widely used in DX A/C systems is developed. Extensive experiments suggest that the use of the H-L control would result in a better control performance, in terms of an improved indoor humidity level and a higher energy-efficiency for DX A/C systems, when compared to the use of traditional On-Off control.
590
$a
School code: 1170.
650
4
$a
Engineering, Architectural.
$3
1671790
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0462
690
$a
0548
710
2
$a
Hong Kong Polytechnic University (Hong Kong).
$3
1020200
773
0
$t
Dissertation Abstracts International
$g
71-11B.
790
1 0
$a
Chan, Ming-yin,
$e
advisor
790
$a
1170
791
$a
Ph.D.
792
$a
2010
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3429796
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9158594
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login