Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
The use of thermal mass and phase ch...
~
Gilbert, Robert B.
Linked to FindBook
Google Book
Amazon
博客來
The use of thermal mass and phase change material to reduce a building's thermal load.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
The use of thermal mass and phase change material to reduce a building's thermal load./
Author:
Gilbert, Robert B.
Description:
125 p.
Notes:
Source: Dissertation Abstracts International, Volume: 71-10, Section: B, page: 6388.
Contained By:
Dissertation Abstracts International71-10B.
Subject:
Engineering, Architectural. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3425232
ISBN:
9781124258317
The use of thermal mass and phase change material to reduce a building's thermal load.
Gilbert, Robert B.
The use of thermal mass and phase change material to reduce a building's thermal load.
- 125 p.
Source: Dissertation Abstracts International, Volume: 71-10, Section: B, page: 6388.
Thesis (Ph.D.)--University of Dayton, 2010.
A finite-difference model is used to simulate the effects of thermal mass and phase change material on thermal transmission through a building's envelope wall. The exterior temperature is simulated by a sinusoidal function. The inside temperature is held constant. A comparison is given between the effects of thermal mass and phase change material. The required climate conditions for thermal mass and phase change material to reduce thermal transmission are given. The maximum reduction in net thermal transmission is given for both thermal mass and phase change material. Equations are given to calculate the minimum thermal load resulting from thermal mass and therefore the maximum thermal load reduction with thermal mass. Equations and methods are given to calculate the minimum thermal load resulting from thermal mass from weather data files, TMY or TMY2 files.
ISBN: 9781124258317Subjects--Topical Terms:
1671790
Engineering, Architectural.
The use of thermal mass and phase change material to reduce a building's thermal load.
LDR
:03219nam 2200301 4500
001
1395449
005
20110518115254.5
008
130515s2010 ||||||||||||||||| ||eng d
020
$a
9781124258317
035
$a
(UMI)AAI3425232
035
$a
AAI3425232
040
$a
UMI
$c
UMI
100
1
$a
Gilbert, Robert B.
$3
1674139
245
1 4
$a
The use of thermal mass and phase change material to reduce a building's thermal load.
300
$a
125 p.
500
$a
Source: Dissertation Abstracts International, Volume: 71-10, Section: B, page: 6388.
500
$a
Adviser: Kelly Kissock.
502
$a
Thesis (Ph.D.)--University of Dayton, 2010.
520
$a
A finite-difference model is used to simulate the effects of thermal mass and phase change material on thermal transmission through a building's envelope wall. The exterior temperature is simulated by a sinusoidal function. The inside temperature is held constant. A comparison is given between the effects of thermal mass and phase change material. The required climate conditions for thermal mass and phase change material to reduce thermal transmission are given. The maximum reduction in net thermal transmission is given for both thermal mass and phase change material. Equations are given to calculate the minimum thermal load resulting from thermal mass and therefore the maximum thermal load reduction with thermal mass. Equations and methods are given to calculate the minimum thermal load resulting from thermal mass from weather data files, TMY or TMY2 files.
520
$a
The IECC, International Energy Conservation Code, allows for a reduction in R-value and/or an increase in U-factor of the exterior wall of a building with the incorporation of what it defines as a MASS WALL within the wall. A study is conducted to determine the required U-factor of the MASS WALL for it to perform with equal net thermal transmission and net thermal load, under transient ambient sol-air temperature conditions, as the required U-factor of the no-mass wall. The IECC defines eight CLIMATE ZONES with different requirements for each. The required U-factors are given for four of the zones. A finite-difference model was developed specifically to simulate the BESTEST qualification cases. This model is used to verify the results obtained when applied within the entire building envelope.
520
$a
A test cell is constructed with a heater and a thermostat within the cell to maintain the interior air temperature at a predetermined set point. The test cell is placed in the ambient cyclic weather conditions. Data is logged of the temperature of the interior cell air, mass wall surfaces, and the ambient air. The amount of energy required to maintain the cell at the set point is also logged. The test cell is placed in different cyclic weather temperature conditions with respect to the interior cell set point temperature. The logged data verifies the conclusions offered resulting from the finite-difference study.
590
$a
School code: 0327.
650
4
$a
Engineering, Architectural.
$3
1671790
650
4
$a
Engineering, Mechanical.
$3
783786
690
$a
0462
690
$a
0548
710
2
$a
University of Dayton.
$3
1021969
773
0
$t
Dissertation Abstracts International
$g
71-10B.
790
1 0
$a
Kissock, Kelly,
$e
advisor
790
$a
0327
791
$a
Ph.D.
792
$a
2010
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3425232
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9158588
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login