語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
An in vitro mechanical comparison of...
~
Bordelon, Jude Thaddeus.
FindBook
Google Book
Amazon
博客來
An in vitro mechanical comparison of TPLO plates.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
An in vitro mechanical comparison of TPLO plates./
作者:
Bordelon, Jude Thaddeus.
面頁冊數:
31 p.
附註:
Source: Masters Abstracts International, Volume: 48-06, page: 3550.
Contained By:
Masters Abstracts International48-06.
標題:
Biology, Veterinary Science. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1477474
ISBN:
9781124051727
An in vitro mechanical comparison of TPLO plates.
Bordelon, Jude Thaddeus.
An in vitro mechanical comparison of TPLO plates.
- 31 p.
Source: Masters Abstracts International, Volume: 48-06, page: 3550.
Thesis (M.S.)--Oklahoma State University, 2010.
Scope and Method of Study. In vitro biomechanical study.
ISBN: 9781124051727Subjects--Topical Terms:
1021733
Biology, Veterinary Science.
An in vitro mechanical comparison of TPLO plates.
LDR
:02333nam 2200301 4500
001
1393273
005
20110311132649.5
008
130515s2010 ||||||||||||||||| ||eng d
020
$a
9781124051727
035
$a
(UMI)AAI1477474
035
$a
AAI1477474
040
$a
UMI
$c
UMI
100
1
$a
Bordelon, Jude Thaddeus.
$3
1671798
245
1 3
$a
An in vitro mechanical comparison of TPLO plates.
300
$a
31 p.
500
$a
Source: Masters Abstracts International, Volume: 48-06, page: 3550.
500
$a
Adviser: Kenneth E. Bartels.
502
$a
Thesis (M.S.)--Oklahoma State University, 2010.
520
$a
Scope and Method of Study. In vitro biomechanical study.
520
$a
Findings and Conclusions. An in vitro mechanical study was performed to compare the fatigue properties and loads to failure of four plate designs used to stabilize the tibial plateau leveling osteotomy (TPLO). Seventy-two gapped osteotomy models were created using 3.5mm versions of the following plates: a standard TPLO plate (SP), a low profile TPLO plate (LoP), a locking TPLO plate (LocP), and a broad locking TPLO plate (bLocP). The eighteen constructs for each plate design were sub-divided into three identical groups of six. Six constructs were mounted in a materials testing device and subjected to cyclic compressive loading until failure was observed or one million cycles were achieved. Additionally, six constructs of each plate design were tested in compressive axial loading and six others in four-point bending in a load to failure manner. To provide residual strength comparisons, the six constructs undergoing cyclic fatigue compression testing were also tested in axial compressive loading. There were not any significant differences in stiffness between plates tested in axial compressive loading. However, mean loads at failure were higher for the LocP and bLocP constructs. The bLocP had a significantly higher mean stiffness and mean load at failure compared to the other constructs tested in four point bending.
590
$a
School code: 0664.
650
4
$a
Biology, Veterinary Science.
$3
1021733
690
$a
0778
710
2
$a
Oklahoma State University.
$b
Veterinary Biomedical Sciences.
$3
1021731
773
0
$t
Masters Abstracts International
$g
48-06.
790
1 0
$a
Bartels, Kenneth E.,
$e
advisor
790
1 0
$a
Rochat, Mark C.
$e
committee member
790
1 0
$a
Ritchey, Jerry W.
$e
committee member
790
$a
0664
791
$a
M.S.
792
$a
2010
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1477474
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9156412
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入